Page Title

Benutzer-Werkzeuge

Webseiten-Werkzeuge


mikeurban:setup:installation_2019_neuin2019

Dies ist eine alte Version des Dokuments!


Neu in MIKE URBAN Version 2019

Modul/Typ Neues Feature/Fehler Status
Model ManagerSimplification Wizard does not visualize new demand allocation connection lines correctlyFixed
Model ManagerRemove multiple results at one click in MIKE URBAN Longitudinal ProfilesFixed
Model Manager (EPANET)Simplification Wizard, demands not moved downstream when there are two or more demands connected to a junction.Fixed
CS-Pipe FlowSuffix “CatchmentDischarge” is added to the catchment MUID disabling MIKE1D from reading the information in Boundary ConditionsFixed
Model Manager (SWMM5)Example1 cannot complete simulation with latest SWMM5 engine versionFixed
Model Manager (SWMM5)Crash when trying to browse a file to import in a specific combination in the Import / Export wizardFixed
Model Manager (SWMM5)Exception error when trying to import from specific inp fileFixed
Model Manager (SWMM5)Catchment Slope and Length: Exception error when clicking No in the Warning dialogFixed
Model ManagerCan't load specific MIKE 1D rainfall runoff result fileFixed
Model ManagerPath for Long profile is not fully controllable and wrong path is loadedFixed
Model ManagerMU DFS2 support does not work with ArcGIS 10.6.1Fixed
Model Manager (EPANET)Demand Statistic dialog does not have copy/paste optionsFixed
Model Manager (MOUSE/MIKE1D)Curves and Relations Dialog, The third column 'As' is not hidden, appears in all curves that should only have two columnsFixed
CS-Pipe Flow (MIKE 1D)MIKE 1D merges the catchment ID and the linked boundary condition type into a single non existing MUID when aiming to run the RDI simulation - causing the simulation to stopFixed
CS-Pipe Flow (MIKE 1D)Cannot derive some results from MIKE 1D network calculation results *.res1dFixed
Model ManagerMU Project Check Tool does not check for duplicate node MUIDsFixed
CS-Pipe FlowError that MIKE URBAN loads a MIKE 1D result file as soon as a simulation is started, if the previous result file is stored in the same folder as the setupFixed
Model Manager (EPANET)PID Control dialog - attributes missing in the "Tools | Customize | Custom Units", mw_PIDFixed
Model Manager (MIKE1D)Problems with MOUSE engine after upgrading a model from MIKE URBAN 2016 to MIKE URBAN 2017Fixed
Model Manager«/td>Problem with SWQ Editor functionality with linking to specified Q-H relation specified in GUIFixed
CS-Pipe FlowMIKE URBAN - UHM model result incorrect if simulation time shorter than lag timeFixed
Model Manager (EPANET)Option for user defined prefix for MUIDs when adding new featuresFixed
Model Manager (SWMM5)Export of transect X and Z values are swappedFixed
CS-Pipe Flow (MIKE 1D, LTS)MIKE 1D LTS: including AD statistics [Discharge_Load_Out] is ommitted from ERF fileFixed
CS-Pipe Flow (MIKE 1D, LTS)MIKE 1D LTS: statistics for AD components not related to event definitionFixed
CS-Pipe Flow (MIKE1D)MIKE 1D truncates RTCFunction.TSConnection1Fixed
mdb template (Primary) should be exported to gdb template.Fixed
Model ManagerOption for user defined prefix for MUIDS when adding new features.Fixed
Model Manager (SWMM5)Problem with loading result itemsFixed
Model Manager (EPANET)The greyed out field beside diameter displaying "diameter - diameter - wall thickness" should be "diameter = diameter – 2 * wall thickness".Fixed
Model Manager ((2D Flood))Changes to the SimulationID does not change the result filename for the .dfs2 in flood simulation causing overwrite of existing result filesFixed
Model Manager (2D Flood)Generate Fish Extent causes MIKE URBAN crash, if decimal separator is set to comma and not dotFixed
Model Manager (2D FLOOD)Changing the Node ID does not cascade to changing the Node ID for the coupled cellsFixed
Model ManagerUpdate of catchment parameters fails (msm_HModA) in the Import / Export toolsFixed
Model Manager (2D FLOOD)"Node Water Level" result list for MIKE 1D flood results viewed in MIKE URBAN incorrectly offers both node and M21 node levelsFixed
Model ManagerExport to ISYBAU format is not workingFixed
Model ManagerThe volume graph for basin storage should be drawn based on calculating many points covering the range of the specified tableFixed
Model Manager (CS-Pipe Flow)MIKE URBAN and ECOLAB - editing built-in constants. The editor field "Global value" (attribute msm_EcolabCoeffvalue) should be disabled if msm_EcolabBuildInID <> -1, which means the values come directly from ECO LabFixed
Model Manager (CS-Pipe Flow)Improvement of the syntax in the LTS statistics result file ERFFixed
Model Manager (CS-Pipe Flow)Problem with MIKE1D engine writing LTS result file ERF in binary formatFixed
Model Manager (SWMM5)SWMM5 should support routing steps in decimalsFixed
Model Manager (CS-Pollution Transport)Catchment processing SWQ concentrations: the tool does not work for multiple componentsFixed
Model ManagerAfter MIKE 1D simulations, result files are not auto loadedFixed
Model Manager (2D FLOOD)Error in 2D OverlandFlow Example with reading Band_1 in DEM.dfs2Fixed
Model Manager (CS-Pipe Flow)Error in MIKE1D engine requiring a Q-H relation table having at least three entries specified – two entries is enough
mikeurban/setup/installation_2019_neuin2019.1553961287.txt.gz · Zuletzt geändert: 2019/03/30 16:54 von thomas