Modul/Typ | Fehler/Neues Feature | Status |
---|---|---|
Model Manager and MIKE 1D | * Enhanced to handle all CRS X-Z OPEN type curves * Validation updates has been assigned to pump structures * Hydrological model B (kinematic wave) handling long timespans * Running Model A running long series of rain events * The entries simulation time is included in the job list created fil, the .mjl file has been improved. | Fixed |
Collection system | * Various issues in SWMM has been fixed which enables complete export of side-flow weirs setups * Catchment dialog grid has been redesigned to fit in different screen resolutions | Fixed |
Collection system | Drainage for bio-retention cells is fully supported - LIDs | New Feature |
Documentation | Documentation regarding curb inlets (2D coupling) has been updated | Fixed |
General | * Scenario Manager handling differences in datatypes between scenarios * The KMD2 time series bridge handling data with multiple digits * Result verification has been enabled to compare res1d with PRF files | Fixed |
Model Configuration | Tool to apply and update errors when working with conflict flags | Fixed |
Project check tool | Soakaway type node is now supported and included | New feature |
Water Distribution | The algorithm for Water Hammer has been fixed to avoid oscillations and crashes while adding check valves in the analysis | Fix |
Modul/Typ | Fehler/Neues Feature | Status |
---|---|---|
Model Manager and MIKE 1D | Added support for Low Impact Development: Bio-retention cell, porous pavement, infiltration trench, rain barrel, vegetative swale, rain garden, green roof | New feature |
GIS extensions | Unable to load DFS2 files into ArcMAP | Fixed |
Documentation | Missing link to MIKE URBAN dedicated ECOLab template in documentation index | Fixed |
Modul/Typ | Fehler/Neues Feature | Status |
---|---|---|
Model Manager | * Fehlerprüfung meldet nicht-kritische Tagesganglinien als Fehler | Fixed |
Flooding | * Kopplung zu nicht existierenden Zellen irrtümlich möglich bei der Verbindung von MIKE 21 FM | Fixed |
MIKE 1D engine | * MIKE 1D kann das Colebrook-White Widerstandsgesetz nicht mit Rückschlagventilen kombinieren | Fixed |
Model Manager | * Wenn MIKE URBAN im minimierten Modus geschlossen wurde, öffnete es sich ebenfalls minimiert. | Fixed |
Model Manager | * Die Orientierung im Wehreditor ist aktiviert wenn "Discharge coeff." definiert ist, auch wenn er nicht benutzt wird. | Fixed |